Laramie County has adopted the following 2021 International Codes with amendments effective January 1, 2022.
National Emission Standard for Hazardous Air Pollutants (NESHAP)
Click here for electronic code copies
At the Laramie County Board of Commissioners public hearing on December 1, 2020, the adoption of the 2020 edition of the National Electrical Code was approved as shown below.
LARAMIE COUNTY DESIGN CRITERIA
RESIDENTIAL
Table R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
SNOW |
WIND DESIGN | SEISMIC DESIGN CATEGORY |
SUBJECT TO DAMAGE FROM |
ICE BARRIER UNDER-LAYMENT REQUIRED |
FLOOD HAZARDS |
AIR FREEZING INDEX |
MEAN ANNUAL TEMP |
|||||
SPEED (mph) Vult |
Topographic Effects | Special Wind Region | Wind-borne debris zone | Weathering | Frost Line depth | Termite | ||||||
25lb/ft2 | 105 | YES | NO | NO | A-B | SEVERE | 36" | NO | NO | 2007 | 2000 | 45 deg |
COMMERCIAL
Ground Snow Load = 25lb/ft2
Frost Line Depth = 36"
All other loading/structural design criteria shall be in accordance with 2021 IBC Chapter 16. *Note: All design criteria shall be provided on code study sheets for all projects.